Features
Virous of actuators, action position is adjustable (such as CM1701)
High switch on and off capacity(15A)
High accuracy
Wide range of operation speed
Each type of CM series has solder terminal, screw terminal and tab terminal are selective
Add A for solder terminal, add C for tab terminal, blank for screw terminal
Ratings
Rated Voltage (V) |
Noninductive Load (A) |
Inductive Load (A) |
Inrush Current | |||||||
Resistance Load | Lamp Load | Inductive Load | Motor Load | |||||||
NC | NO | NC | NO | NC | NO | NC | NO | NC | NO | |
125VAC 250VAC 500VAC |
15 15 3 |
3 2.5 1.5 |
1.5 1.25 0.75 |
15 15 2.5 |
5 3 1.5 |
2.5 1.5 0.75 |
30 max. | 15 max. | ||
8VDC 14VDC 30VDC 125VDC 250VDC |
15 15 6(2) 0.4 0.2 |
3 3 3 0.4 0.2 |
1.5 1.5 1.5 0.4 0.2 |
15 10 5 0.05 0.03 |
5 5 5 0.05 0.03 |
2.5 2.5 2.5 0.05 0.03 |
Characteristics
Operation speed | 0.01mm-1m/sec |
Operating frequency | Mechanical: 240 operations/min. |
Electrical: 20 operations/min. | |
Contact resistance | 15mΩ max. (initial value) |
Insulation resistance | 100mΩ min. (at 500VDC) |
Dielectric strength | 1000VAC, 50/60HZ for 1 minute between terminals of the same polarity |
1500VAC, 50/60 HZ for 1 minute between currentcarrying and non-current-carrying metal parts | |
1500VAC, 50/60 HZ for 1 minute between each terminal and ground | |
Vibration frequency | 10-55HZ,1.5mm double amplitude |
Shock | Mechanical durable: 1, 000m/Sec2 (about 100G'S) Malfunction: 300m/Sec2 (about 30G'S) |
Ambient temperature | General purpose type: -25ºC to +80ºC, Sealed type: -15ºC to +80ºC |
Humidity | General purpose type: 85% RH max., Sealed type: 95% RH max. |
Life | Mechanical: 20,000,000 operations min. Electrical: 500,000 operations min. |
Weight | About 22g to 58g |
Degree of protection | IP65 |
Operating characteristics
Models | CM1300 | CM1301 | CM1303 | CM1305 | CM1306 | CM1307 | CM1308 | CM1309 | CM1701 |
OF Max. | 350g | 300g | 300g | 350g | 350g | 350g | 350g | 350g | 70g |
RF Min. | 114g | 50g | 50g | 114g | 114g | 114g | 114g | 114g | 14g |
PT Max. | 0.4mm | 4mm | 4mm | 0.4mm | 0.4mm | 0.4mm | 0.4mm | 0.4mm | 10mm |
OT Min. | 0.13mm | 1.6mm | 1.6mm | 1.6mm | 1.6mm | 5.5mm | 3.58mm | 3.58mm | 5.6mm |
MD Max. | 0.05mm | 1.3mm | 1.3mm | 0.05mm | 0.05mm | 0.05mm | 0.05mm | 0.05mm | 1.27mm |
FP Max. | 20.6mm | 31.8mm | 28.2mm | ||||||
OP(mm) | 15.9 ±0.4 mm | 17.4 ±0.8 mm | 28.6 ±0.8 mm | 28.2 ±0.5 mm | 21.5 ±0.5 mm | 21.50. ±8 mm | 33.4±1.2 mm | 33.4±1.2 mm | 19 ±0.8 mm |
Models | CM1702 | CM1703 | CM1704 | CM1705 | CM1743 |
OF Max. | 160g | 100g | 160g | 10g | 160g |
RF Min. | 28g | 22g | 42g | 3g | 42g |
PT Max. | 5mm | 7.1mm | 2.7mm | 20mm | 2.7mm |
OT Min. | 2mm | 4mm | 2.4mm | 5.6mm | 2.4mm |
MD Max. | 1mm | 1.02mm | 0.5mm | 3mm | 0.5mm |
FP Max. | 24.8mm | 36.5mm | 32.5mm | 43.6mm | |
OP(mm) | 19 ±0.4 mm | 30.2 ±0.8 mm | 30.2 ±0.4 mm | 19±0.4 mm | 43.1 ±0.8 mm |
Definitions of operating characteristics:
- OF: operating force
Force needed to add to the executer unit to actuate switch contact
RF: releasing force
Force needed to add to the execter unit to make the switch contact back to normal position
TF: total force
Force needed to make executer unit move from free position to limitation position
FP: free position
Primary position of executer unit without external force adding to executer unit
OP: operating position
The position of executer unit in case of the contact rapidly moving to the contact position for action
RP: releasing position
The position of executer unit in case of the contact rapidly backing to normal position to action contact position
TTP: total tavel position
The position of executer unit in case of executer unit reaching the limitation position
PT: pretravel
The distance or angle that the executer unit passes since free position to action position
OT: overtravel
The distance or angle that the executer unit surpasses action position
MD: movement differential
The distance or angle from action position to reversion position
TT: total tavel
The distance or angle represents the movement till action and the total movement after all actions.